Home Page
Company Profile
Our Products
Water Treatment Chemicals
Fuel Additives
Boiler Chemical
Cooling Tower Chemicals
R.O Chemical
Descaling Chemicals
Chilling Plant Chemical
Resin Cleaning Chemical
Decarbonising Chemical
Oxygen Scavenger
Boiler Water Side Chemical
Boiler Fire Side Chemical
Cleaning Chemical
Boiler Cleaning Chemical
Cooling Tower Cleaning Chemical
Membrane Cleaning Chemical
Heat Exchanger Chemical
Furnace Oil Additives
Thermopack Cleaning Chemical
Online Boiler Chemical
offline Boiler Chemical
pH Booster Chemical
RO Membrane Cleaning Chemical
Cation/Anion Exchange Resin
Ion Exchange Resin
Softener Resin
Cation Exchange Resins
Anion Exchange Resin
Water Softner Resin
Non Regenerative Resin
Super Charged Resin
Demineralisation Plant Resin
D M Plant Resin
Contact Us
 

 
 
 
Home » Products » Cooling Tower Cleaning Chemical » Cooling Tower Cleaning Chemical

Cooling Tower Cleaning Chemical



Cooling Tower Cleaning Chemical

Product Code : 022

Product Specification

Purpose of Cooling Tower Cleaning Chemical :
The primary reasons for chemical cleaning of boilers/ heat exchangers are to prevent tube failures & improve unit availability. Tube failures in low pressure boilers/heat exchangers are normally the results of creep which occurs when internal deposits produce excessive metal temperature. A relatively smaller quantity of deposit creates difficulties in high pressure boilers. Caustic corrosion & hydrogen damage, which occur only in the presence of deposits, may cause tube failures at temperatures well below the creep limit. Deposits originating both from fabrication & during operation should be considered potential problems.

All the pressure parts of steam generator may be subjected to heat treatment of some sort during fabrication or erection during forming operations, stress relief, welding or bending. Whenever carbon low alloy steels are subjected to high temperatures in the presence of air, oxidation occurs, the oxide produced is known as mill scale. Mill scale on boiler/ heat exchanger tubing is normally very thin with the exception of areas near welds & bends. Even where mill scale is initially uniform its brittleness upon cooling may produce flaking. The resulting non-uniform surface is undesirable from the standpoint of corrosion susceptibility. During operation mill scale is rapidly eroded from the steam generating surfaces & may subsequently be redeposited in critical areas. Preoperational acid cleaning removes mill scale & serves to remove atmospheric rust which inevitably accumulates to some degree during erection.

After a boiler / heat exchanger placed into service, numerous solid constituents may enter the units with the feed water & some portion of the insolubles can be expected to deposit on surfaces. If not removed these deposits accumulated over a period of time can minimize the quantity of these materials; however, complete freedom from deposition is not possible in a high pressure system. The need for occasional chemical cleaning during the life of the equipment has become a recognized fact & should be accepted as a routine maintenance practice. A frequency of service cleaning of every 3 to 4 months is recommended. This frequency should be increased if individual unit operating history dictates.

                                         OFF LINE COOLING TOWER CLEANING  CHEMICA

COOLING TOWER  CHEMICAL is designed to remove the scaling& corrosion products from boiler& cooling water circuits , heat changers etc. It is a liquid formulation to remove hardness & low concentrated silica scales that can be removed offline by circulating its dilute solution of the chemical. It is a balance formulation of  Hydrochloric Acid, Dispersant Wetting Agents & Corrosion Inhibitor.

BENEFITS

POWERFUL DESCALENT.

COOLING TOWER  CHEMICAL is safe & non-corrosive for  descaling ,it dissolves hardness scales quickly & complectly..

SAFE FOR METALS .

BOILER CLEANING CHEMICAL contains a synthetic polymeric corrossion inhibitor which forms protective film on the parent metal surface to prevent acid  attack .

DETERGENT ACTION .

COOLING  CLEANING CHEMICAL contains a wetting agent which emulsifies oil grease present in the deposits. The detergent action of Aquablend-DS loosens dirt ,silt,algae etc which can be removed  during water flushing. 

APPLICATION.

CLEANING CHEMICAL  should be dosed in 5-10 % solution in water . warm water may be used for faster action . normally the quantity of scale required depends upon the operating condition quantity of scales and hold up , Numatik Engineers Pvt Ltd  will provide technical assistance to setup optimum dosage according to operating  conditions  and system.

STORAGE & HANDLING 

COOLING TOWER CLEANING CHEMICAL should be stored in an air tight container away from direct heat. Always store at cool & dry place.. Wash thoroughly with water in case of contact. Do not swallow.

COOLING TOWER CLEANING CHEMICAL is available in 20 Kg & 35 Kg. HDPE CARBOY.

 

Until now, your choices in treatment systems were limited:
You could obtain an unreliable, minimum-capability system from your chemical supplier¦
Or you could spend your design resources on a custom-built system.
Either way, it was hard to get the right combination of capability and cost.
We have Solution for above problems they are:

Aquablend 04 Scale 
AQUABLEND- 04 is a liquid formulation designed protects ferrous as well as copper equipment from recirculating cooling water system. It contains no heavy metal formulation and powerful scale inhibitor to control precipitation of calcium phosphates, carbonate & sulphate. Along with a catalyst it also contains dispersant to keep suspended matter such as silt, metal oxides, etc in dispersed form avoiding deposition on heat exchangers.

Aquablend QAT  Biocide 

AQUABLEND-QAT is biodegradable ,wide spectrum organic liquid micro biocide based on quaternary ammonium compounds used in industrial recirculating cooling water systems. AQUABLEND-QAT controls build up of biological slimes & sulphate reducing bacteria.

Aquablend PNT  Biocide 
AQUABLEND-PNT is a powerful anti foulant for treatment of recirculating cooling water. It is a wide spectrum  liquid microbiocide for checking microbiological growth. AQUABLEND-PNT controls build up of trouble-some bactria in industrial cooling water.a powerful dispersant keeps slit & similar foulants in suspension.

Aquablend CBT  Biocide 
AQUABLEND-PNT is a powerful anti foulant for treatment of recirculating cooling water system. It is a wide spectrum liquid micro biocide for checking microbiological growth. AQUABLEND-PNT controls build up of trouble-some bacteria in industrial cooling water powerful dispersant keeps slit & similar foulants in suspension.

<< Back






Contact Details
NUMATIK ENGINEERS PVT. LTD.
6, Bobby Pathak Avenue, Near Corporation Bank, Opp. Rotary Garden, C.S. Complex, Dahisar (E), Mumbai - 400068, Maharashtra, India
Phone:91-22-28480866/28482642/28480100/28483848
Fax:91-22-28480100
Email Us : water.tech60@yahoo.com
Send SMS
Key Personnel
Mr. Manu C. Patel (Director)
Mobile:+919820684990, +919820684981


 
 
Copyright © 2011-12 by NUMATIK ENGINEERS PVT. LTD. All Rights Reserved.