Home Page
Company Profile
Our Products
Water Treatment Chemicals
Fuel Additives
Boiler Chemical
Cooling Tower Chemicals
R.O Chemical
Descaling Chemicals
Chilling Plant Chemical
Resin Cleaning Chemical
Decarbonising Chemical
Oxygen Scavenger
Boiler Water Side Chemical
Boiler Fire Side Chemical
Cleaning Chemical
Boiler Cleaning Chemical
Cooling Tower Cleaning Chemical
Membrane Cleaning Chemical
Heat Exchanger Chemical
Furnace Oil Additives
Thermopack Cleaning Chemical
Online Boiler Chemical
offline Boiler Chemical
pH Booster Chemical
RO Membrane Cleaning Chemical
Cation/Anion Exchange Resin
Ion Exchange Resin
Softener Resin
Cation Exchange Resins
Anion Exchange Resin
Water Softner Resin
Non Regenerative Resin
Super Charged Resin
Demineralisation Plant Resin
D M Plant Resin
Contact Us
 

 
 
 
Home » Products » Softener Resin » Water Softening Chemicals

Water Softening Chemicals



<< Previous   Water Softening Chemicals

Product Code : 0125      Brand Name :numatik aqua

Product Specification

Water Softening Chemicals :

Water Softening Resin is a natural or synthetic compound which begins in a highly viscous state and hardens with treatment. Typically, this chemical is soluble in alcohol, but not in water. There are a number of different classes of resin, depending on exact chemical composition and potential uses. There are numerous applications for resins, ranging from art to polymer production, and many consumers interact with products which contain resin on a daily basis.

3 Steps for Resin Cleaning for Softner & DM -

1. Backwashing Phase: This removes dirt from the mineral tank and is part of the regeneration process
2. Regeneration Phase: The mineral tank is recharged with sodium from the brine tank solution and displaces calcium and magnesium, 
    which is then washed down the drain during the Backwashing Phase.
3. Rinse Phase: The mineral tank is rinsed with fresh water and loads the brine tank so that it is ready for the next cycle.

As water passes through the mineral tank, the positively charges calcium and magnesium ions are lost to negatively charged plastic beads. The brine tank holds a solution of water and salt that will flush the mineral tank and replace the calcium and magnesium ions with sodium. Recharging cycles are controlled by the meter on the top of the tank (normally once every 7 days).

RESIN CLEANING CHEMICALS :- 
CATION RESIN CLEANING COMPOUND 
AQUABLEND-RCC IS AN ONLINE CATION RESIN CLEANING COMPOUND FOR PREVENTION OF ORGANIC FOULING & HEAVY METAL FOULING OF RESIN. IT IS A BLEND OF SEVERAL SURFACTANTS & IRON SOLUBULISING AGENT.

 

AQUABLEND-RCC

CATION RESIN CLEANING COMPOUND

AQUABLEND-RCC IS AN ONLINE CATION RESIN CLEANING COMPOUND FOR PREVENTION OF ORGANIC FOULING & HEAVY METAL FOULING OF RESIN. IT IS A BLEND OF SEVERAL SURFACTANTS & IRON SOLUBULISING AGENT.

 

PRODUCT  DETAILS

1. PREVENT RESIN FOULING & ASSURED QUALITY OUTPUT

AQUABLEND-RCC REDUCES THE PROGRASSICE FOULING OF CATION RESIN DUE TO OIL & SUSPENDED SOLIDS , HELPS IN KEEPING THE RESIN BEAD SURFACE CLEAN . REGULAR USE OF AQUABLEND-RCC REDUCES REGENERATION FREQUENCY, SERVICE CYCLE & EXTENDS LIFE OF THE RESIN.

2. APPLICATION

AQUABLEND-RCC ONLONE 
IT CAN BE ADDED TO THE RINSE CYCLE OF EVERY REGENERATION. ONLINE CLEANING IS CARRIED OUT DURING THE RINSE CYCLE. THE RECOMMONDED DOSE IS 1 KG FOR 1000 LTR. OF RESIN.

AQUABLEND-RCC OFF-LONE 
- DRAIN WATER UP TO THE RESIN LEVEL AFTER REGENERATION & RINSE CYCLE.
- ADD AQUABLEND-RCC AT THE RATE OF 15 KG. FOR 1000 LTR. RESIN.
- AGITATE USING COMPRESS AIR TO MIX IT WITH RESIN & RINSE AFTERWORDS.
- AFTER 30 MIN. FINAL RINSE REGENERATION WITH 100 % EXCESS SALT.
- TAKE  INTO THE SERVICE LINE.

3. HANDLING & STORAGE

AQUABLEND-RCC IS AN ACIDIC COMPOUNDS MAY CAUSE IRRITATION WITH SKIN. AVOID CONTACT WITH EYES AND NOSE. IN CASE OF CONTACT WASH WITH PLENTY OF FRESH WATER. DO NOT SWOLLOW. KEEP CONTAINER DRY, CLOSED & AWAY FROM DIRECT HEAT.

AQUABLEND-RCC IS AVAILABLE IN STANDARD PACKING OF 20 KG. 

 

ANION RESIN CLEANING COMPOUND 

AQUABLEND-RCA  IS AN ONLINE ANION RESIN CLEANING COMPOUND FOR PREVENTION OF ORGANIC FOULING & BIOLOGICAL FOULING OF RESIN. IT IS A BLEND OF SEVERAL SURFACTANTS & BIOLOGICAL PREVENTIVE AGENT.

AQUABLEND-RCA

ANION RESIN CLEANING COMPOUND

AQUABLEND-RCA IS AN ONLINE ANION RESIN CLEANING COMPOUND FOR PREVENTION OF ORGANIC FOULING & BIOLOGICAL FOULING OF RESIN. IT IS A BLEND OF SEVERAL SURFACTANTS & BIOLOGICAL PREVENTIVE AGENT.

 

PRODUCT  DETAILS

1. PREVENT RESIN FOULING & ASSURED QUALITY OUTPUT

AQUABLEND-RCA REDUCES THE PROGRASSICE FOULING OF ANION RESIN DUE TO OIL & SUSPENDED SOLIDS. IT ALSO PREVENTFOULING OF RESIN DUE TO MICROBIOLOGICAL GROWTH THUS KEEPING THE RESIN BEAD SURFACE CLEAN. REGULAR USE OF AQUABLEND-RCA REDUCES REGENERATION FREQUENCY, SERVICE CYCLE & EXTENDS LIFE OF THE RESIN.

2. APPLICATION

AQUABLEND-RCA ONLONE 
IT CAN BE ADDED TO THE RINSE CYCLE OF EVERY REGENERATION. ONLINE CLEANING IS CARRIED OUT DURING THE RINSE CYCLE. THE RECOMMONDED DOSE IS 1 KG FOR 1000 LTR. OF RESIN.

AQUABLEND-RCA OFF-LONE 
- DRAIN WATER UP TO THE RESIN LEVEL AFTER REGENERATION & RINSE CYCLE.
- ADD AQUABLEND-RCA AT THE RATE OF 15 KG. FOR 1000 LTR. RESIN.
- AGITATE USING COMPRESS AIR TO MIX IT WITH RESIN & RINSE AFTERWORDS.
- AFTER 30 MIN. FINAL RINSE REGENERATION WITH 100 % EXCESS REGENERANT.
- TAKE  INTO THE SERVICE LINE.

3. HANDLING & STORAGE

AQUABLEND-RCA IS AN ALKALINE COMPOUNDS MAY CAUSE IRRITATION WITH SKIN. AVOID CONTACT WITH EYES AND NOSE. IN CASE OF CONTACT WASH WITH PLENTY OF FRESH WATER. DO NOT SWOLLOW. KEEP CONTAINER DRY, CLOSED & AWAY FROM DIRECT HEAT.

AQUABLEND-RCA IS AVAILABLE IN STANDARD PACKING OF 20 KG. 

  

Other Products in 'Softener Resin ' category
Water Softener Resin
Water Softener Resin
 
<< Back






Contact Details
NUMATIK ENGINEERS PVT. LTD.
6, Bobby Pathak Avenue, Near Corporation Bank, Opp. Rotary Garden, C.S. Complex, Dahisar (E), Mumbai - 400068, Maharashtra, India
Phone:91-22-28480866/28482642/28480100/28483848
Fax:91-22-28480100
Email Us : water.tech60@yahoo.com
Key Personnel
Mr. Manu C. Patel (Director)
Mobile:+919820684990, +919820684981


 
 